Please use this identifier to cite or link to this item: https://repository.southwesthealthcare.com.au/swhealthcarejspui/handle/1/3552
Journal Title: Assessment of acetabular version in total hip arthroplasty: an application of Widmer's technique in a regional setting
Authors: Trieu, Jason
Hadden, Alexandra E. F.
Sutherland, Alasdair G.
SWH Author: Trieu, Jason
Sutherland, Alasdair G.
Keywords: Orthopaedic
Hip Replacement
Hip Arthroplasty
Assessment
Acetabular
Issue Date: 2018
Date Accessioned: 2023-03-17T04:57:29Z
Date Available: 2023-03-17T04:57:29Z
Url: https://onlinelibrary.wiley.com/doi/10.1111/ans.14506
Format Startpage: 573-576
Source Volume: 88
Issue Number: 6
DOI: 10.1111/ans.14506
Abstract: BACKGROUND: Acetabular prosthesis positioning in total hip arthroplasty is important in reducing the risk of dislocation. Assessment of version by computed tomography scan is expensive and involves a large radiation dose. We wished to assess the value of Widmer's technique, utilizing readily available radiographs, to determine cup anteversion. METHODS: Patients who underwent primary total hip arthroplasty by the senior author (AGS) at a single regional hospital over a 5-year period were eligible for inclusion. Measurements were performed using the technique described by Widmer, utilizing standard post-operative radiographs. Statistical analysis was undertaken in SPSS v22. Significance was accepted at P < 0.05. RESULTS: Assessment included 109 hips in 99 patients; 63 hips with cemented cups and 46 hips with uncemented cups. Mean acetabular anteversion in the cemented group was 11.9° (0-27.7, SD: 7) and in the uncemented group was 14.1° (10.3-32.7, SD: 7.1); this difference trended towards statistical significance (P = 0.09). Test-retest measurements showed high degree of correlation (Pearson test: 0.927, P < 0.001). There were 96 of 109 hips positioned in the Lewinnek safe zone of 5-25° anteversion. The crude dislocation rate in our cohort was 6.4% (7 of 109 hips) with all dislocations occurring in hips placed in the safe zone. CONCLUSION: Widmer's technique is a reliable method for calculating acetabular version in a regional hospital setting and offers the individual surgeon a ready technique of personal quality control. Cup version was not a significant factor contributing to dislocation rates in our series.
URI: https://repository.southwesthealthcare.com.au/swhealthcarejspui/handle/1/3552
Journal Title: ANZ Journal of Surgery
Type: Journal Article
Appears in Collections:SWH Staff Publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Google Media

Google ScholarTM

Who's citing